COMPANY PROFILE
About
Common trouble shooting of nipple drinker
Trouble | Reason | Trouble shooting |
1、Water leak at push rod of the nipple | A、Impurities enter in the nipple | Lift push rod up with the finger, wash away impurities or remove the nipple for washing |
B、Nipple is not Installed in place | Re install | |
2、Water leakage at nipple housing | A、The cracks in the shell | Replace |
B、 The rear rubber ring is not installed in place | Re install the nipple drinker, if it is ring problem, replace the rubber ring | |
3、No water from nipple | A、Nipple outlet blocked | Unloading nipple device, flushing water pipe and nipple seat |
B、Water pipe line is not leveled | Leveling the pipe line | |
C、Water pipe line has gas blocking phenomenon | Repeated push the rod or remove the nipple to discharge gas |